Solar Calculator Canada

Solar Power Calculator for Port Alice, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Port Alice
  • GPS Coordinates: 50.426667, -127.488056
  • Elevation: 11 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Port Alice: 35o
  • Average yearly irradiance: 1121.33 kWh/m2
  • Average yearly power output: 92369.6 kWh
Sun Path Port Alice

Average yearly irradiance delivered by the Sun in Port Alice is 1121.33/kWh/m2 at the optimal panel slope of 35o. After taking all losses into account, you can expect about 92369.6 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 35o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.1 33.97
February 2 55.97
March 2.53 78.35
April 3.82 114.54
May 4.58 142.08
June 4.58 137.3
July 5.32 164.89
August 4.8 148.7
September 3.75 112.63
October 2.01 62.27
November 1.26 37.72
December 1.06 32.91
Total yearly 1121.33

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 91.83 2846.8
February 169.88 4756.51
March 214.47 6648.48
April 322.73 9681.78
May 378.47 11732.5
June 373.16 11194.9
July 427.6 13255.5
August 386.24 11973.4
September 306.3 9188.96
October 165.56 5132.29
November 105.54 3166.34
December 90.07 2792.13
Total yearly 92369.6

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Port Alice solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 70.42 2183.14
February 140.39 3930.97
March 198.11 6141.44
April 314.89 9446.63
May 384.89 11931.6
June 389.64 11689.2
July 436.91 13544.2
August 379.55 11766.2
September 280.02 8400.61
October 144.5 4479.46
November 82.43 2472.8
December 64.68 2005.09
Total yearly 87991.3

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 76.91 2384.17
February 149.52 4186.44
March 203.97 6323.12
April 319.01 9570.38
May 385.49 11950.1
June 387.89 11636.7
July 436.92 13544.6
August 383.7 11894.6
September 288.75 8662.61
October 151.28 4689.74
November 89.35 2680.36
December 72.15 2236.78
Total yearly 89759.6

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 82.73 2564.54
February 157.53 4410.8
March 208.7 6469.79
April 321.55 9646.61
May 384.32 11914
June 384.44 11533.1
July 434.79 13478.4
August 385.84 11961
September 295.79 8873.71
October 157.1 4869.97
November 95.53 2865.81
December 78.93 2446.81
Total yearly 91034.5

Port Alice Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 87.88 2724.25
February 164.44 4604.19
March 212.3 6581.15
April 322.49 9674.81
May 381.51 11826.7
June 379.31 11379.3
July 430.55 13347.1
August 385.97 11965
September 301.12 9033.52
October 161.94 5020
November 100.97 3029.13
December 85 2635.06
Total yearly 91820.2

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.84% angle of incidence loss and -5.8% temperature and irradiance loss. This totals to about -17.62%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.